The lock-in technique for studying magnetoelectric effect
Giap V. Duong a, b, R. Groessinger a, M. Schoenhart a and D. Bueno-Basques c
a Institute for Solid State Physics, Vienna University of Technology, Wiedner Hauptstrasse 8-10, 1040 Vienna, Austria
b Faculty of Chemical Engineering, Hanoi University of Technology, Dai Co Viet, Hai Ba Trung, Hanoi, Vietnam
c CIMAV, Miguel de Cervantes, 120°, 31109 Chihuahua, Mexico
Abstract
Measuring techniques for studying the magnetoelectric (ME) effect are not established yet. In this work, we report about a lock-in technique for studying the ME effect in ME-multiferroic composites. The philosophy as well as the theory of measurement is discussed. The advantages and disadvantages of this method are described. Details on our experimental set-up in which an AC field with frequencies ranging from 1 to 10 kHz and amplitudes from 1 to 20 Oe are superimposed onto a DC bias field up to 15 kOe are shown. Treatments of the zero-signal and operation modes are demonstrated. ME investigations on CoFe2O4-BaTiO3 composites are discussed in details.
Schlagworte:
Magnetoelectric effect; Lock-in technique; Measuring technique; Dynamic method; Multiferroic composite
"Offizielle" elektronische Version der Publikation (entsprechend ihrem Digital Object Identifier - DOI)